IICRC Standards Explained: S500, S520, S700, S540, S100 and More

a revision is in development; not published as of October 2026

S500 — Water damage restoration

Fifth Edition, 2021

From October 1, 2026 Connecticut requires contractors to do mold remediation in accordance with S520

S520 — Mold remediation

Fourth Edition, 2024

IICRC’s first fire and smoke standard

S700 — Fire and smoke damage restoration

First Edition, 2025

assumes scenes have been released by law enforcement or regulators

S540 — Trauma and crime scene cleanup

Second Edition, 2023

IICRC standards set out how professional restoration, cleaning and remediation work is performed, in consensus documents such as S500, whose Fifth Edition, 2021, is the current water damage standard.

The core titles: ANSI/IICRC S500 for water damage restoration, S520 for mold remediation, S700 for fire and smoke damage restoration, S540 for trauma and crime scene cleanup, and S100 for textile floor coverings, with S300, S800 and others alongside.

This page maps what each covers, which roles use which day to day, whether following one is legally required, and how a standard differs from a certification.

What is an ANSI/IICRC standard?

An ANSI/IICRC standard is a voluntary consensus document: it is developed and revised by a consensus body balanced among producers, users and general-interest members, working under ANSI-accredited procedures.

IICRC describes its standards as accepted as the “Standard of Care” in the industry, its own phrase for the shared playbook a restoration crew works from.

The content is concrete, not abstract.

S500 defines Category 3 water as “grossly contaminated” water that can contain pathogenic, toxigenic or other harmful agents, with sewage and seawater flooding among its examples.

And where mold growth is found or suspected on a water job, S500 refers the restorer to the current S520.

The standards cross-reference each other the way a job crosses loss types.

The standards also script the first hour: S500 lists a site-specific safety survey, verifying the water source and establishing dry standards and drying goals among a water restorer’s minimum initial-response activities.

Editions move, and that is the part readers get caught on.

S500’s Fifth Edition, published in 2021, follows editions in 1994, 1999, 2006 and 2015, and a new S500 Consensus Body has begun work on the next revision.

The Fifth Edition, 2021, is the current one as of October 2026.

If a blog or a job posting cites a newer S500 edition, it cites an edition that has not been published.

What a standard is not matters as much.

It is not a law, not a license, and not a certification.

Each of those confusions gets its own section below, because all three come up on real job sites and in real job postings.

Looking for restoration technician jobs? Browse open positions →

What does each standard cover (S500, S520, S700, S540, S100, S800)?

Each standard covers one body of work: some titles map straight onto restoration losses, and the rest cover floor care, commercial buildings, HVAC and specialty remediation.

The table lists the ANSI/IICRC standards this page’s research confirmed on their iicrc.org pages in October 2026.

StandardCoversCurrent edition (October 2026)
S100Professional Cleaning of Textile Floor CoveringsSeventh Edition, 2021.
S220Inspection of Hard Surface Floor CoveringsSecond Edition, 2026.
S300Professional Upholstery CleaningSecond Edition, 2025.
S400Cleaning, Maintenance and Restoration of the Commercial Built EnvironmentFirst Edition, 2025.
S410Cleaning of the Built Environment for Infection Prevention and ControlFirst Edition, 2025.
S500Professional Water Damage RestorationFifth Edition, 2021.
S520Professional Mold RemediationFourth Edition, 2024.
S540Trauma and Crime Scene CleanupSecond Edition, 2023.
S590Assessment of HVAC Systems Following a Water, Fire, or Mold Damage EventFirst Edition, 2023.
S700Professional Fire and Smoke Damage RestorationFirst Edition, 2025.
S800Professional Inspection of Textile Floor CoveringsSecond Edition, 2023.
S900Remediation of Precursors, Drug Residues, and Associated Chemical WasteFirst Edition, 2025.

S500 — water damage restoration.

IICRC lists components including building and material science, psychrometry and drying technology, equipment and instruments, antimicrobial technology, structural restoration, HVAC restoration, and contents evaluation, restoration and remediation.

A sixth edition is in development but was not published as of October 2026.

For the job-level detail (shall vs should, categories of water, drying goals, file review), the IICRC S500 guide goes deep.

S520 — mold remediation.

IICRC lists components covering the principles of mold remediation, mold cleaners and antimicrobial chemicals and coatings, remediator qualifications, safety and health, inspection and preliminary determination, structural, HVAC and contents remediation, post-remediation verification, and the indoor environmental professional.

OSHA’s mold page describes the standard as establishing mold contamination definitions and its conditions 1, 2 and 3, with guidance for deciding when remediation is triggered and confirming success.

S700 — fire and smoke damage restoration.

It is the new one: the First Edition, 2025, is IICRC’s first fire and smoke standard, and a revision has already begun.

IICRC says the standard covers assessing the presence, intensity and boundaries of fire residues and odors in buildings, systems such as HVAC, and contents, for fires inside the building or in adjoining or nearby buildings.

It does not comprehensively address reconstruction, wildfires, chemical or industrial fires, or special-requirement buildings such as healthcare facilities and clean rooms.

S540 — trauma and crime scene cleanup.

IICRC lists components including safety and health, antimicrobial biocide technology, structural, vehicle and contents remediation, packaging, transport and disposal of regulated or potentially infectious waste, and confirmation of cleaning.

The standard assumes scenes have been released by law enforcement or regulatory agencies.

The document starts where the police work ends.

S100, S220, S300 and S800 — floor and textile care.

S100 is the carpet cleaner’s document: professional cleaning of textile floor coverings, Seventh Edition, 2021, with revision work underway.

S300 covers upholstery cleaning, S800 covers inspecting textile floor coverings, and S220 covers hard-surface floor inspection, at Second Edition, 2026.

S400, S410, S590 and S900 — commercial, HVAC and specialty.

S400 covers cleaning, maintenance and restoration of the commercial built environment, and S410 covers cleaning for infection prevention and control, both First Editions, 2025.

S590 covers assessing HVAC systems after a water, fire or mold damage event, and S900 covers remediating drug residues and associated chemical waste.

Four more were still under development as of October 2026, carrying the BSR/IICRC prefix IICRC uses for standards that are not yet ANSI-approved.

The drafts: S230 for subfloor and substrate inspection, S250 for resilient floor coverings, S530 for indoor environment assessment of suspected mold, and S320 for contents assessment, cleaning and restoration.

S320 was out for public review from September 11 to October 26, 2026, so check iicrc.org for whether it has published since.

Numbers outside this grid (S770 and S760 come up in forums) were not confirmed in our research.

Place every standard number on IICRC’s own pages before you repeat it.

IICRC is not the only standards body a restoration crew touches.

NADCA publishes the ACR standard for assessing, cleaning and restoring HVAC systems.

The 2025 edition is offered as a free download.

ASTM publishes the test methods behind concrete slab moisture checks: F2170 for in-situ relative humidity and F1869 for moisture vapor emission rate.

Which roles use which standard day to day?

Each role uses the standard for its loss type day to day.

A tech who crosses loss types changes documents with the job:

  • Water mitigation technicians — S500 frames the mitigation job, with S590 joining when the loss reaches HVAC systems.
  • Mold remediation technicians — S520 for the remediation job, from inspection and preliminary determination through structural, HVAC and contents remediation and post-remediation verification, taking the mold scope S500 hands off on a water job.
  • Fire restoration technicians — S700 for assessing fire and smoke residues and odors in buildings, systems and contents, with S590 again for the HVAC assessment.
  • Biohazard and trauma scene technicians — S540 once a scene is released, and S900 where the job is drug residue rather than blood.
  • Carpet and duct cleaning technicians — S100, S300, S800 and S220 in the floor- and textile-care world, while duct cleaning’s standard comes from another body: NADCA’s ACR.
  • Restoration technicians — the generalist role that crosses all of the above, changing standards as the loss changes; the restoration technician career guide covers the umbrella role.

Commercial losses add S400 and S410 to the shelf.

Crew leads, estimators and project managers read the same documents from the other direction.

A standard supplies the categories, conditions and checkpoints that a scope of work, a job file and a walkthrough get measured against.

Whichever row you sit in, it is worth seeing how live postings phrase their standard-and-certification requirements: browse restoration technician jobs.

Is following the standard legally required?

No, not on its own: the standards describe the industry’s professional standard of care, and the law sits beside them, not underneath.

IICRC describes the standards as voluntary consensus documents.

OSHA’s own mold page describes the S520 (its definitions, its conditions 1, 2 and 3, its guidance on when remediation is triggered) and files it with other consensus standards under an explicit caveat: these are not OSHA regulations.

Inside the documents, though, requirement language still tells a crew what the standard of care includes.

On a Category 2 or 3 water loss, S500 says remediation should happen before restorative drying and restorers shall use contamination controls and appropriate worker protection.

The documents even define what stays optional: S500 defines “can” as a possibility open to the user that is not part of the accepted standard of care.

The requirements with legal force around a restoration job come from regulators, and the standards point there themselves.

S700 says that when regulated hazardous materials are suspected, restorers shall perform work consistent with the authority having jurisdiction’s regulations.

Federal rules attach to the work directly: under asbestos NESHAP, the owner or operator of a covered facility must thoroughly inspect the affected part for asbestos before renovation, including restoration tear-out after water and fire losses.

NESHAP’s facility definition leaves out most residential buildings with four or fewer dwelling units, and state programs may be stricter.

EPA’s lead RRP rule treats emergency renovations (unplanned work resulting from a sudden, unexpected event such as a water or fire loss) as exempt from some requirements only to the extent needed to respond.

Cleaning, cleaning verification and recordkeeping still apply.

One state rule in this research names a standard outright.

From October 1, 2026, Connecticut’s Home Improvement Act includes water, fire or storm restoration and mold remediation on residential property (Public Act 26-100).

Connecticut issues a home improvement contractor certificate to a contractor who does mold remediation only with an attestation that the contractor is certified in mold remediation by the IICRC, NORMI or another organization the DCP commissioner approves.

The same law requires contractors to perform mold remediation in accordance with ANSI/IICRC S520 (the Fourth Edition) or a DCP-approved successor.

That is what it looks like when a statute picks up a standard: the edition is named, and a successor clause keeps the requirement current.

Where a state licenses mold work outright, the license, not the standard, is the legal requirement, and the standards keep doing their day job as the professional playbook.

The state mold licensing guide covers how those regimes work.

Standards move, and so do the rules around them

S520 was revised in 2024 and S700 first appeared in 2025, and state rules change alongside them. Confirm the current edition with the IICRC before you buy or cite it, and confirm the requirements that bind a specific job with the authority having jurisdiction, OSHA, EPA or your state agency.

How do standards differ from certifications?

A standard is a document; a certification is a credential a person earns.

The standard describes how the work should be performed.

IICRC certification requires attending an IICRC-approved course, passing the written exam and documenting skills in the subject.

Because the IICRC issues both, the same initials sit on both sides of the pairing.

In practice the pairings line up by loss type.

The Water Damage Restoration Technician (WRT) certification has no prerequisites and covers water damage effects and drying techniques, the S500 body of work.

The Applied Microbial Remediation Technician (AMRT) certification requires the WRT first and emphasizes mold and sewage remediation, the S520 side.

On the fire side, the Fire and Smoke Restoration Technician (FSRT) certification covers scoping, mitigation, cleaning, deodorization and documentation of fire- and smoke-damaged structures and contents.

The difference shows in what each one answers.

Asked what Category 3 water is, you open the standard; asked whether a tech is trained, the certification is the evidence.

A crew can work from a purchased standard with no certified tech on it, and a wallet full of certificates does not put the standard’s definitions into a job file.

Following the document and holding the credential are separate things.

The certification system has its own track: prerequisites, exams, cost, CECs and renewal.

Start with the IICRC certification guide for the credential side, and keep this page for the documents.

How do techs get access to the standards?

Techs get access to the standards by buying them.

IICRC sells its standards through the Gilmore Global webstore (iicrc.gilmoreglobal.com), and a digital copy is licensed to one user and may not be shared.

So a shop that wants its own copies buys its own seats.

The free layer is the summary.

Each standard’s public page on iicrc.org lists its components and scope, which is enough to know what a standard covers before anyone purchases it.

The component lists summarized above come from those pages.

Watch for dead ends, though.

IICRC no longer develops or revises its old “reference guides” (R520, the mold reference guide, is among them) and treats them as historical documents, so an old R-guide is not a substitute for the current standard.

The standard itself is the document to buy.

The class route runs in parallel.

IICRC courses walk through the matching body of knowledge: WRT for the water side, AMRT for mold and sewage, FSRT for fire.

Every IICRC class is run by an approved third-party school or instructor.

The IICRC is a certifying body that owns no schools.

The IICRC classes guide covers formats and providers.

One habit covers the whole shelf: check the edition before you buy, cite or scope against it.

Several standards were in active revision or development as of October 2026, so the catalog on iicrc.org is the list to check.

Career information, not licensing, legal, insurance, health or safety advice. Confirm current standard editions with the IICRC, and the requirements that bind a specific job with the authority having jurisdiction, OSHA, EPA or your state agency.

Frequently Asked Questions

How often are IICRC standards updated?

IICRC standards are updated standard by standard, each time IICRC seats a new consensus body for that title.

As of October 2026, revision work was underway on S500, S540, S700, S100 and S590, and four more standards (S230, S250, S320 and S530) were still in development.

Check iicrc.org for the edition in force before you buy or cite one.

Is the IICRC S520 an OSHA regulation?

No. OSHA’s mold page describes the S520 (its conditions 1, 2 and 3 framework and its guidance on when remediation is triggered) and lists it among consensus standards with the explicit caveat that these are not OSHA regulations.

Rules with legal force come from regulators: on restoration and mold work that includes OSHA’s workplace standards, EPA’s asbestos and lead rules, and state licensing or registration where a state runs one.

Is there an IICRC S770 standard?

Our research did not confirm S770 or S760 in the IICRC catalog as read in October 2026.

The floor-covering and textile titles our research confirmed are S100 (cleaning), S220 (hard-surface inspection), S300 (upholstery cleaning) and S800 (textile inspection), and S230, S250, S320 and S530 were still in development.

IICRC’s own standards page is the list to check.

Do IICRC standards and certifications mean the same thing?

No. A standard is a document describing how the work is performed; a certification is a credential a technician earns by attending an approved course, passing the written exam and documenting skills in the subject.

In practice they line up by loss type: the WRT certification covers water damage effects and drying techniques (the S500 body of work), while the AMRT requires the WRT first and emphasizes mold and sewage remediation, the S520 side.

Which IICRC standard applies to crime scene cleanup?

ANSI/IICRC S540, the Standard for Trauma and Crime Scene Cleanup, currently the Second Edition, 2023, with a revision underway.

IICRC lists components covering safety and health, structural, vehicle and contents remediation, and packaging, transport and disposal of regulated or potentially infectious waste, and the standard assumes scenes have been released by law enforcement or regulatory agencies.

Related Career Guides

Ready to work to the standards? Browse open restoration technician jobs →