Restoration Equipment List: The Tools Water, Fire and Mold Techs Run

A sixth edition is in development but unpublished as of October 2026

The water-drying standard

ANSI/IICRC S500, Fifth Edition (2021)

EPA, citing the U.S. Department of Energy definition

What HEPA means

99.97% of 0.3-micron particles

Guidance for water-damaged areas and items — EPA calls it only a guideline

EPA drying window

24 to 48 hours

Building guidance for context — not a drying goal; the S500 has the restorer establish dry standards and drying goals

EPA indoor RH guidance

Below 60%, ideally 30% to 50%

Restoration equipment falls into five working groups: extraction gear that pulls water out, drying equipment that evaporates and dehumidifies, HEPA air filtration that captures particles, the meters and cameras that measure progress, and the cleaning, containment, PPE and documentation tools that hold a job together.

This page is the master index of that list for water, fire and mold technicians: what each category does and the standards and ratings behind it.

What is on a typical water mitigation truck?

A typical water mitigation truck carries extraction, drying, air filtration, moisture measurement, containment and PPE, and documentation gear.

The loadout changes with the loss, but those categories hold steady.

They are not arbitrary: ANSI/IICRC S500, the water damage restoration standard (Fifth Edition, 2021, with a sixth edition in development but unpublished as of October 2026), lists equipment and instruments and psychrometry and drying technology among the components it describes procedures for.

Extraction is where a wet job starts.

EPA's clean-water guidance for wet carpet tells the crew to remove water with a water extraction vacuum, lower humidity with a dehumidifier and speed drying with fans.

It is one loop: pull the water out, then take it out of the air.

Pumps and portable extraction units are the hardware side of that first step.

A water truck also carries containment and PPE, and the reason is contamination.

The S500 defines Category 3 water as grossly contaminated, with sewage, waste-line backflows from beyond any trap, seawater and rising water from rivers or streams among its examples.

On Category 2 and 3 losses, the S500 says remediation should happen before restorative drying and that restorers shall use contamination controls and appropriate worker protection.

EPA's clean-water drying table does not even apply to sewage-contaminated (or chemically or biologically polluted) water, where OSHA requires personal protective equipment and containment.

The rest of the truck, by group:

  • Drying: air movers, LGR and desiccant dehumidifiers, and controlled heat on some jobs.
  • Air filtration: HEPA air scrubbers and negative air machines (the HEPA-filtered fan units EPA's guidance describes), plus HEPA vacuums for cleanup.
  • Measurement: moisture meters, a thermo-hygrometer and a thermal imaging camera.
  • Containment and PPE: polyethylene sheeting, respirators, gloves and coveralls.
  • Documentation: a camera and the job file: photos, moisture readings and the dry standards and drying goals the S500 has the restorer establish.
Looking for restoration technician jobs? Browse open positions →

What drying and dehumidification equipment will you run?

The drying and dehumidification equipment you will run is air movers and dehumidifiers.

Air movers do the evaporating: they are the fans EPA's clean-water table uses to speed drying, moving air across wet surfaces.

Dehumidifiers do the capture: they take moisture out of the air so wet materials keep drying.

Two dehumidifier designs you will hear named are LGR units and desiccants.

On how many a job takes, our research found no public source for an air-mover placement formula or dehumidifier sizing factors, and the S500 itself is paywalled.

The numbers a crew can actually verify are the job's own moisture readings and the ratings each manufacturer publishes for its own machines.

Ratings are where new techs get tripped.

The current federal (DOE) test procedure for residential portable dehumidifiers rates capacity at 65°F dry-bulb and 60% relative humidity; whole-home dehumidifiers are tested at 73°F.

Manufacturer spec sheets quote their own rating points, so compare capacities measured at the same conditions before you compare machines.

Heat is part of some drying setups.

EPA's clean-water table suggests dehumidifiers, fans and/or heaters for wet concrete or cinder block, and dehumidifiers, gentle heat and fans for wood, with a caution about applying heat to hardwood floors.

On timing, EPA guidance says water-damaged areas and items should be dried within 24 to 48 hours to prevent mold growth.

EPA calls that window "only a guideline": mold will not always grow after 48 hours, and it can grow even when materials are dried within 48 hours.

One more thing the drying setup plugs into: power.

On construction sites, OSHA requires ground-fault circuit interrupter protection on all 120-volt, single-phase 15- and 20-amp receptacles that are not part of the building's permanent wiring.

Those are the temporary outlets a bank of air movers and dehumidifiers runs on, where the construction standards apply.

What air filtration and containment gear is used?

The air filtration and containment gear used on restoration jobs is built around HEPA filters, the word that governs this shelf of the truck.

EPA, citing the U.S. Department of Energy definition, says a HEPA filter can theoretically remove at least 99.97% of airborne particles 0.3 microns in size.

OSHA's asbestos standard defines it the same way: a filter that traps and retains at least 99.97% of mono-dispersed particles 0.3 micrometers in diameter.

Under EPA's lead RRP rule, a HEPA vacuum is a machine where the HEPA filter is the last filtration stage and all the air leaves through the filter with no leakage past it.

Air scrubbers and negative air machines are the HEPA-filtered fan units EPA's guidance describes holding containments under negative pressure, and the containment around them decides how they run.

EPA's mold guide sizes jobs as small, medium and large at 10 and 100 square feet of affected surface area.

For 10 to 100 square feet of mold, EPA generally recommends limited containment: polyethylene sheeting floor to ceiling around the affected area, with a slit entry and covering flap.

The sheeting is a single layer of 6-mil fire-retardant polyethylene, held under negative pressure from a HEPA-filtered fan unit, with supply and return vents blocked.

Above 100 square feet, or wherever occupied space would otherwise be contaminated, EPA describes full containment: two layers of fire-retardant polyethylene with one airlock chamber, kept under negative pressure by a HEPA-filtered fan exhausted outside the building.

EPA also stresses that containment size is a judgment call: a small, heavily contaminated area may warrant full containment, while a large, lightly contaminated, easily cleaned wall may need only limited containment.

Where the job is an asbestos negative-pressure enclosure, OSHA's construction asbestos rule puts numbers on the setup: at least 4 air changes per hour and at least -0.02 inches water column relative to outside, shown on a manometer and kept negative throughout use.

On mold jobs, EPA's guidance describes negative pressure from a HEPA-filtered fan unit.

The air-change and pressure figures above are the asbestos enclosure rule's, and they are not a mold-remediation spec.

HEPA vacuums come out at the end of mold work: EPA recommends them for final cleanup after materials are thoroughly dried and contaminated materials are removed, with the vacuum's contents disposed of in well-sealed plastic bags.

PPE rides with the containment.

EPA's mold guide tiers it: minimum PPE is gloves, an N-95 respirator and goggles; limited PPE adds an N-95 or half-face respirator with HEPA filter plus disposable overalls; full PPE is disposable full-body clothing, head gear, foot coverings and a full-face respirator with HEPA filter.

The tiers above come from EPA's mold guide; mold remediation PPE and respirators cover what techs wear in detail.

Containment and PPE figures change — check the source

The containment tiers, PPE tiers and asbestos enclosure figures above come from EPA guidance and OSHA rule text, and agencies revise both. Confirm the current EPA mold guidance and OSHA construction standards before you build a containment or pick respiratory protection for a job.

What meters and cameras do techs carry?

Techs carry a thermo-hygrometer for the air, moisture meters for materials and a thermal imaging camera for surfaces.

Relative humidity alone does not say how much moisture the air holds, because RH depends on both moisture content and temperature.

That is why restorers also track dew point (the temperature to which air must be cooled to reach saturation) and grains per pound, a scale built on the conversion of 7,000 grains to the pound.

The drying science behind those readings is psychrometry in structural drying, covered on its own page.

For context on where indoor air sits, EPA recommends keeping relative humidity below 60%, ideally between 30% and 50%.

That is ordinary building guidance, not a drying goal: the dry standard a restoration job works to is one the restorer establishes for that job under the S500.

Moisture meters come in two families.

Pin meters measure moisture content from the direct-current conductance of wood; pinless, dielectric meters use surface-contact electrodes.

Pinless readings are dominated by the surface layers and may not represent a wet core when there is a large moisture gradient through the material.

Pins with insulated shanks read moisture only at the pin tips, which is what lets a tech trace a moisture gradient through a board.

The wood numbers have boundaries worth knowing.

In wood, moisture can be measured reliably from 4% to about 30% with commercial dielectric meters and from about 6% to 30% with resistance meters; above 30%, readings are only qualitative.

Resistance readings need a temperature correction of about 0.5% moisture content per 10 degrees Fahrenheit away from the calibration temperature, plus a species correction where the manufacturer supplies one.

Both scales sit around a threshold with a name: the fiber saturation point, where the cell walls are saturated and the free water is gone, which averages about 30% moisture content but varies by several percentage points between species and pieces.

Wood holds its water two ways — free water in the cell cavities and bound water within the cell walls — and that line is where the free water has left.

Concrete calls for different instruments: ASTM F2170 is the standard test method for relative humidity inside a concrete floor slab using in situ probes, and ASTM F1869 measures the moisture vapor emission rate of a concrete subfloor using anhydrous calcium chloride.

The thermal imaging camera rounds out the kit.

It shows temperature differences on surfaces (it does not read moisture), so a cold spot flags a candidate area, and a meter confirms what the camera found.

The readings are only as useful as the record behind them.

The S500's minimum initial-response activities include verifying the water source, identifying the extent of the water migration, arriving at a preliminary determination and establishing dry standards and drying goals.

The instruments above are what a tech takes those readings with.

What fire, mold and contents equipment is added?

Fire, mold and contents jobs each add their own equipment to the water kit.

Mold work adds demolition and application tools to the containment kit from the last section: the hand tools that cut out wallboard and trim, and the sprayers that apply antimicrobials where the scope calls for them.

The standard for professional mold remediation, ANSI/IICRC S520, is in its Fourth Edition (2024).

EPA does not recommend routine use of biocides such as chlorine bleach in mold remediation; its stated reason is that the goal is to remove mold, not just kill it.

Antimicrobial products that claim to kill mold or germs are regulated as pesticides, and apart from listed exemptions, only registered products can be distributed or sold.

Every pesticide label carries the federal statement that using the product in a manner inconsistent with its labeling is a violation of law.

Dilution, dwell time and application method follow the label.

Blasting units are another mold-equipment family, with dry ice and soda media among them.

Dry ice is solid carbon dioxide, and the gas it becomes has exposure limits.

Those include an OSHA permissible exposure limit of 5,000 ppm as an 8-hour time-weighted average, a NIOSH short-term limit of 30,000 ppm and a NIOSH IDLH of 40,000 ppm.

Those limits matter when dry-ice blasting in enclosed spaces such as attics and crawl spaces.

Fire and smoke jobs add soot-cleaning tools and odor control equipment on top of the drying and filtration gear above.

EPA's caution covers one familiar machine: no federal agency has approved ozone generators for use in occupied spaces, and at concentrations not exceeding public health standards, ozone in indoor air does not effectively remove viruses, bacteria, mold or other biological pollutants.

Smoke odor removal methods and the fire and smoke restoration process cover the fire-side kit as a tech works it.

Contents and pack-out work brings its own gear: packing materials, an inventory process and, for wet documents, freezing or freeze-drying.

EPA advises discarding non-valuable wet books and papers, photocopying valuable ones, or freezing them in a frost-free freezer or meat locker or freeze-drying them.

Contents are a first-class part of the standard too: the S500 lists contents evaluation, restoration and remediation among the components its procedures cover.

What do employers expect a new tech to know?

Employers expect a new tech to know the equipment groups, the vocabulary and the handful of figures that come up on every water job.

Know what each machine category does, and know that capacity ratings depend on the test conditions behind them: the federal test for portable residential dehumidifiers runs at 65°F dry-bulb and 60% relative humidity.

Know HEPA at 99.97% of particles at 0.3 microns, and GFCI-protected temporary power where the construction standards apply.

And know what pin and pinless meters actually read, including the corrections wood readings need.

Contamination vocabulary matters as much as the hardware.

The S500's Category 3 definition and its requirement for contamination controls and worker protection on Category 2 and 3 losses explain why a mitigation truck carries containment and PPE alongside the drying equipment.

A tech who can explain that clearly (on site or to an adjuster) is doing the job, not just running machines.

Documentation closes the loop.

The S500's initial-response list runs from a site-specific safety survey through a preliminary determination to establishing dry standards and drying goals, and the readings a tech logs are what document the equipment run against that plan.

On the credential side, one IICRC water restoration credential is the WRT (Water Damage Restoration Technician).

It has no prerequisites, runs live-stream and in person (and in Spanish), and covers water damage effects and drying techniques.

That includes changing drying plans based on the Science of Drying.

IICRC certification is its own subject on the page linked here: which credentials exist, what the course and exam take, what renewal costs in effort.

An IICRC certification is a credential, not a license; where a state licenses mold or asbestos work, that licensing is a separate, state-by-state question.

For people new to the trade, the restoration technician career guide covers the role itself (what the work spans, where it happens and how techs move up), and open restoration technician jobs show what employers are hiring for right now.

Career information for people in or entering restoration work — not legal, safety or equipment advice for a specific job. Confirm the current rule with the agency or body that publishes it (OSHA, EPA or the IICRC) before you rely on it on a job.

Confirm the current rule before you rely on a figure

The figures on this page (test conditions, HEPA definitions, containment and PPE tiers, exposure limits) come from EPA guidance, OSHA rules and the IICRC standards as those sources stood when they were read, and they change. Confirm the current text with OSHA, EPA or the IICRC before you set a job up, and treat manufacturer ratings as the manufacturer's own claims.

Frequently Asked Questions

What does HEPA mean on restoration equipment?

High-efficiency particulate air.

EPA, citing the Department of Energy definition, says a HEPA filter can theoretically remove at least 99.97% of airborne particles 0.3 microns in size.

Under EPA's lead RRP rule, a HEPA vacuum is one where the HEPA filter is the last filtration stage and all the air leaves through it with no leakage.

Why do dehumidifier pint ratings differ between spec sheets?

Capacity depends on the conditions it was measured at.

The current federal (DOE) test procedure rates portable residential dehumidifiers at 65°F dry-bulb and 60% relative humidity, and whole-home units at 73°F.

Manufacturer spec sheets quote their own rating points, so compare capacities only at the same temperature and humidity.

Do air movers and dehumidifiers need GFCI outlets?

It depends: on construction sites, OSHA requires ground-fault circuit interrupter protection on all 120-volt, single-phase 15- and 20-amp receptacles that are not part of the building's permanent wiring.

Those are the temporary outlets a bank of drying equipment runs on where the construction standards apply.

Whether a specific restoration job falls under the construction standards depends on the work.

What is the difference between pin and pinless moisture meters?

Pin meters read moisture from the direct-current conductance of wood; pinless, dielectric meters use surface-contact electrodes, and their readings are dominated by the surface layers.

Pins with insulated shanks read only at the tips, which shows moisture gradients through a board.

In wood, commercial dielectric meters read reliably from 4% to about 30% and resistance meters from about 6% to 30%; above 30%, readings are qualitative only.